no image

Taltal No. 61 Engine Spec

<kuid:65931:52003>

Author: RPearson
Kind: steam-engine
Build: 2.7
Size: 5.33KB
Uploaded: 2019-03-03
Loadings:
35
-
0
+

Taltal No. 61 Engine Spec

This engine spec is based on a maximum tractive effort of 27615 lbs and a max hp of 650@ 28 mph at rail head. Max speed is set at 20 mph for DCC operation - with CAB mode speeds above 40 mph are possible. The power curve used as a basis for setting this spec was developed with the tzSTEC program and should represent a realistic approximation of the locomotive's performance. The parameters used above are in some cases changed from actual values for use in Trainz to give a more prototypical performance within the limitations of the Trainz steam physics system. In particular piston area has been reduce based on piston-max-vol (cylinder vol) and boiler-to-piston-flow to obain a starting TE consistent with the prototype. Piston-min/max-volumes have been increased to obtain prototypical water consumption rates.

For use in TRS2004 the TE at starting is set to 120% of the prototype's rated performance - to compensate for the TRS2004's incorrect effect of gravity on grades - and reduces to 100% at 28+ mph. In TRS2006 the included steam-power curve will give 100% at starting.

No of axles has been increased form 6 to 53 to account for increased resistance of steam locomotives - approx 20lbs resistence/ton of weight on drivers.

Author: Robert R. Pearson

    Taltal No. 61 Engine Spec
  • config.txt 7.60KB

This is a new eng spec file for Peter Pardoe-Matthew's Taltal No 61 model, a Kitson Meyer 0-6-0 0-6-0 tank locomtive. This file MAY NOT BE DISTRIBUTED with or as part of any payware item(s) where any fee or monetary value is charged. All rights retained by the author.
copyright 2005 Robert R. Pearson

VE48: This asset uses an obsolete trainz-build number. Trainz-build numbers below 3.5 are no longer supported.
VE44: Tag 'firebox-volume' in the container 'steam' is obsolete.
VE44: Tag 'firebox-to-boiler-heat-flow' in the container 'steam' is obsolete.
VE44: Tag 'westinghouse-volume' in the container 'steam' is obsolete.
VE44: Tag 'main-reservoir-volume' in the container 'steam' is obsolete.
VE44: Tag 'piston-to-atmosphere-flow' in the container 'steam' is obsolete.
VE44: Tag 'boiler-to-piston-flow' in the container 'steam' is obsolete.
VE44: Tag 'firebox-to-boiler-heat-flow-idle' in the container 'steam' is obsolete.
VE44: Tag 'max-fire-coal-mass' in the container 'steam' is obsolete.
VE61: Required tag 'blower-effect' was missing and has been set to default.
VE61: Required tag 'blower-max-flow' was missing and has been set to default.
VE61: Required tag 'boiler-efficency' was missing and has been set to default.
VE61: Required tag 'boiler-efficency-idle' was missing and has been set to default.
VE61: Required tag 'boiler-efficency-min' was missing and has been set to default.
VE61: Required tag 'cutoff' was missing and has been set to default.
VE61: Required tag 'firebox-heating-surface-area' was missing and has been set to default.
VE61: Required tag 'hand-brake-max-force' was missing and has been set to default.
VE61: Required tag 'ideal-coal-mass' was missing and has been set to default.
VE61: Required tag 'max-coal-mass' was missing and has been set to default.
VE61: Required tag 'number-cylinders' was missing and has been set to default.
VE61: Required tag 'number-power-strokes' was missing and has been set to default.
VE61: Required tag 'speed' was missing and has been set to default.
VE61: Required tag 'steam-chest-max-flow' was missing and has been set to default.
VE61: Required tag 'steam-chest-volume' was missing and has been set to default.
VE61: Required tag 'super-heating-constant' was missing and has been set to default.
VE61: Required tag 'valve-lap-percent' was missing and has been set to defau

Фотографии пользователей

Еще никто не добавил фото этого объекта